F106
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction
Features
Simple cost effective way to provide component protection with
minimal space required eliminating design restraints.
Fits into a standard manifold SAE O-ring Port.
CP Circuit Protector Filters provide backup protection when
upstream pressure filters go into bypass or if element damage
occurs.
CP-SAE provides operations protection through supply of a
bypass to assure flow to critical components if filter becomes
clogged.
Increased range of product use through three (3) different sizes
available, 15 at 4 gpm, 40 at 12 gpm, and size 120 at 30 gpm.
Suitable for petroleum based fluids.
Flow Path - inside to outside.
CP-SAE Series
Circuit Protector Manifold Cartridge Filters
6090 psi • up to 30 gpm
B
A
Technical Specifications
Mounting Method
CP-SAE-15
CP-SAE-40
CP-SAE-120
SAE-10 Port (5/8”)
SAE-16 Port (1)
SAE-24 Port (1 1/2”)
Flow Direction Inlet: Bottom Outlet: Side
Construction Materials
CP-SAE-15
CP-SAE-40
CP-SAE-120
Carbon steel
Carbon steel
Stainless steel
Flow Capacity
CP-SAE-15
CP-SAE-40
CP-SAE-120
4 gpm (15 lpm)
12 gpm (45 lpm)
30 gpm (113 lpm)
Housing Pressure Rating
Max. Allowable Working
Pressure
Fatigue Pressure
Burst Pressure
6090 psi (420 bar)
Contact HYDAC Office
Contact HYDAC Office
Element Collapse Pressure Rating
W 100 psid (6.9 bar)
Fluid Temperature Range 14°F to 21F (-10°C to 100°C)
Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility
Compatible with all petroleum oils rated for use with Nitrile rubber
(NBR) seals.
Bypass Valve Cracking Pressure
P = 50 psid (3.4 bar) +10% (standard)
Replacement Elements
Part Number Description Flow Rate
02069397 0015 D 010 W 0015 - 4 gpm
02069398 0040 D 010 W 0040 - 12 gpm
02069399 0120 D 010 W 0120 - 30 gpm
F107
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model Code
CP-SAE W 15 G 10 W 1 . 0 / 12 B3.5 .
Filter Type
CP-SAE = Circuit Protector
(SAE O-ring Port)
Element Media
W = Wire Mesh
Size
15 = 4 gpm 40 = 12 gpm 120 = 30 gpm
Inline Port
G = Male Threaded
Filtration Rating (micron)
10 = 10 micron 75 = 75 micron 149 = 149 micron
Bypass Indicator
W = No indicator Port
Type Number
1 = Standard Configuration
Modification Number
Port Configuration
12
Bypass Valve
B3.5 = 50 psi
Seals
(omit) = Nitrile rubber (NBR) (standard)
V = Fluorocarbon elastomer (FKM)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Pressure Drop Curves
Based on testing conducted with 150 SUS fluid at 105˚F.
0
0
10
20
30
40
50
0
75/141 µm
0.68
2.06
3.44
10 µm
246810
0 7.57 20.8 33.1
Q (gpm)
CP-SAE 15
ΔP in psi
ΔP in bar
Q (l/min)
0
0
10
50
20
30
40
0
75/141 µm
0.68
10 µm
2.06
3.44
5101520
0 18.9 37.8 56.7 75.6
Q (gpm)
CP-SAE 40
ΔP in psi
ΔP in bar
Q (l/min)
0
0
10
20
30
40
50
0
0.68
2.06
75/141 µm
10 µm
3.44
10 20 30 40
0 37.8 75.6 113.4 151.2
Q (gpm)
CP-SAE 120
ΔP in psi
ΔP in bar
Q (l/min)
15 = 5/8” SAE 10 Port-Threaded
40 = 1” SAE 16 Port-Threaded
120 = 1 1/2” SAE 24 Port-Threaded
F108
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model A B C D
E SAE
O-Ring Port
F G H J
Torque
Alu. Steel
CP-SAE 15 1.00/25.4 0.41/10.4 1.75/44.5 0.74/18.8 -10 (7/8-14) 2.41/61.2
1.12/28.4 min
1.87/47. 5 m a x
0.266/6.8
0.781/19.8 min
0.814/20.7 max
65
ft-lb
85
ft-lb
CP-SAE 40 1.5/38.1 0.5/12.7 2.50/63.5 1.00/25.4 -16 (1 5/16-12) 3.34/84.8
1.49/37.8 min
2.53/64.3 max
0.531/13.5
1.140/29.0 min
1.1875/30.1 ma x
150
ft-lb
200
ft-lb
CP-SAE 120 2.13/5 4.1 0.65/16.5 4.00/101.6 1.50/38.1 -24 (1 7/8-12) 5.01/127.3
1.92/48.8 min
3.81/96.8 max
0.875/22.2
1.750/44.5 min
1.803/45.8 max
230
ft-lb
305
ft-lb
Dimensions
CP-SAE
G
F
H
H
J
0.030 Max Radius
0.076
Or Chamfer
Manifold Filter
Cavity Confi
g
uration
F
B
A
A
A
C
D
OUTLET PORT
Filter
Element (10 Micron
Wire Cloth Standard)
50 P. S.I.D.
Bypass Valve
(Initial Cracking)
Bypass
Valve Assembly
INLET PORT
Size 15, 40, 120
Weight (lbs.) 1.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element.